Product Identification

Product ID:Z-SPAR WHITE UNDERCOAT 105, 609701000000096
MSDS Date:11/01/1987
FSC:8010
NIIN:00N022318
MSDS Number: BLSGY

Responsible Party
KOP-COAT INC
436 SEVENTH AVE SUITE 1850
PITTSBURGH, PA 15219-1818
US

Emergency Phone: 800-553-5631;800-424-9300(CHEMTREC)

Info Phone: 800-323-6571;412-227-2155

Cage: 00297

Contractor
KOP-COAT INC
PITTSBURGH, PA 15219-1818 US

Telephone: 800-553-5631, CHEMTREC 800-424-9300

Cage: 00297

Ingredients

PUB. 80-106 "WORKING IN A CONFINED SPACE".

RTECS: 9999999ZZ


BELOW FLAMM VAP CONC. LOC EXHST NEC FOR USE IN

RTECS: 9999999ZZ


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: <20%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


ZINC OXIDE

CAS: 1314-13-2

RTECS: ZH4810000

Fraction By Weight: <5%

OSHA PEL 15MG/M3 TDUST/5 FUME

ACGIH TLV: 10MG/M3 TDUST; 9293


TALC (CONTAINING ASBESTOS)

CAS: 14807-96-6

RTECS: MW2700000

Fraction By Weight: <40%

OSHA PEL 0.2 FIBERS/CC

ACGIH TLV: 0.2 FIBERS/CC; 9192


MINERAL SPIRITS

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: <30%


AROMATIC HYDROCARBON

CAS: 68333-88-0

Fraction By Weight: <2%


BLASTING, SANDING OR GRINDING. EMPTY CNTNRS MAY

RTECS: 9999999ZZ


NOT CUT, DRILL, GRIND OR WELD ON/NEAR FULL, PARTIALLY

RTECS: 9999999ZZ


CONTACT LENS WITH OUT PROPER EYE PROTECTION WHEN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:CONT OF LIQ MAY CAUSE IRRIT. SKIN:
PRLNGD/RPTD CONT MAY CAUSE IRRIT &/OR DERM. INHAL:INHAL OF HIGH
CONC OF VAP MAY CAUSE RESP TRACT IRRIT & CNS DEPRESS CHARACTERIZED
BY HDCH, WEAKNESS, DIZZ. PRLNG D/RPTD INHAL OF HIGH CONC OF
AIRBORNE PARTICULATED MAY LEAD TO PULM CHANGES. INGEST:MAY CAUSE GI
(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DISTURBANCES SUCH AS NAUS, VOMIT,
DIARR. ASPIR OF MATL INTO LUNGS MAY OCCUR LEADING TO CHEM PNEUMIT
WHICH CAN BE FATAL. OTHER:INHAL OF ZINC OXIDE FUMES CAUSES METAL
FUME FEVER CHARACTERIZED B Y RESP TRACT IRRIT, DRY THROAT, METAL
TASTE, COUGH, NAUS, VOMIT, CHILLS, LETHARGY, MUSCLE CRAMPS.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PRE-EXISTING
DISEASE IN OR A HISTORY OF AILMENTS INVOLVING SKIN, RESP TRACT, CNS
ARE AT GREATER THAN NORMAL RISK OF DEVELOPING ADVERSE EFTS WHEN
WORKING WITH THIS MATERIAL.

First Aid

First Aid:EYE:IMMEDIATELY FLUSH WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES. GET MD. SKIN:WASH THOROUGHLY WITH SOAP & WATER.
IF IRRITATION PERSISTS, GET MD. INHAL:MOVE FROM EXPOSURE. IF BRTHG
HAS STOPPE D OR IS DFCLT, GIVE ARTF RESP/O2 AS NEEDED. GET MD.
INGEST:DO NOT INDUCE VOMIT. GIVE 1-2 GLASSES OF MILK. GET MD IMMED.
DO NOT ATTEMPT TO GIVE ANYTHING BY MOUTH TO UNCON PERS. NOTE TO MD:
(SUPP DATA)

Fire Fighting

Flash Point Method:TCC
Flash Point:105F,41C
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, FOAM OR WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA AND FULL
PROTECTIVE EQUIPMENT . USE WATER TO COOL FIRE-EXPOSED CNTNR/
STURCTURE/PROT PERS. TOX VAPS MAY BE GIVEN OFF IN A FIRE
Unusual Fire/Explosion Hazard:WHEN HEATED (FIRE CNDTNS), VAPS/DECOMP
PRODS MAY BE RELD FORMING FLAMM/EXPLO MIXTURES IN AIR. CLSD CNTNRS
MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT (SUPP DATA)

Accidental Release

Spill Release Procedures:STOP LEAK IF NO RISK INVOLVED. STAY UPWIND.
SMALL WET SPILLS:TAKE UP WITH SAND OR OTHER NONCOMBUSTIBLE
ABSORBENT MATERIAL. FLUSH AREA WITH WATER. DIKE LARGE SPILLS FOR
LATER DISPOSAL. CONTAIN RUNOFF F ROM FIRE CONTROL AND DILUTION
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN AREAS/BLDGS DESIGNED TO
COMPLY W/ OSHA 1910.106. KEEP IN CLSD, LABELED CNTNR W/IN COOL
(WELL SHADED), DRY- VENT AREA. PROT FROM PHYSICAL DAMA
Other Precautions:KEEP CNTNRS CLSD WHEN MATL NOT IN USE. MAINTAIN GOOD
HOUSEKEEPING. NOT FOR USE/STORAGE IN/AROUND HOME. GROUND & BOND
DRUMS. DO NOT PRESSURIZE EMPTY DRUMS. AIRBORNE PARTICULATES MAY BE
GENERATED DURING REMOVAL OPERS INCL ABRASIVE (SEE ING 6)

Exposure Controls

Respiratory Protection:IF VENT DOES NOT MAINTAIN INHAL EXPOS BELOW TLV
(PEL), USE NOSH/MSHA APPRVD UNTIS AS PER CURRENT 29 CFR1910.134 AND
MANUFACTURERS "INSTRUCTIONS" & "WARNINGS". IF WITHIN OSHA
PROTECTION FACTOR, NIOSH/M SHA AIR PURIFYING OV/FILTER UNITS OK.
Ventilation:PROVIDE SUFFICIENT GEN/LOC EXHST VENT IN PATTERN/VOLOME TO
CNTRL INHAL EXPOS BELOW CURRENT EXPOS LIMITS/AREAS(SEE ING 9)
Protective Gloves:INDUSTRIAL RESISTANT FLEXIBLE-TYPE.
Eye Protection:CHEM WORK GOG W/FULL LENGTH FSHLD
Other Protective Equipment:INDUSTRIAL-TYPE WORK CLTHG/SAFETY FOOTWEAR.
RESIST GARMENTS SUCH AS HEAD/NECK
COVER/APRONS/JACKETS/PANTS/COVERALLS/ BOOT
Work Hygienic Practices:WASH EXPOSED AREAS PROMPTLY & THORO AFTER SKIN
CONTACT AND BEFORE EATING, DRINKING, USING TOBACCO PRODUCTS OR REST
ROOMS
Supplemental Safety and Health
EXPLO HAZ:(FIRE). VAPS ARE HEAVIER THAN AIR & MAY TRAVEL ALONG GROUND,
PIT OR SEWER LINE TO SOME DISTANT SOURCE OF IGNITION & FLASH BACK.
FIRST AID PROC:THERE IS NO SPECIFIC ANTIDOTE FOR EFFECTS FROM
OVEREXPOSURE. TREATMENT SHOULD BE DIRECTED AT THE CONTROL OF
SYMPTOMS OF THE CLINICAL CONDITION.

Chemical Properties

HCC:F4
Vapor Density:>1
Spec Gravity:12.2
Evaporation Rate & Reference:SLOW (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE VISCOUS PAINT WITH HYDROCARBON ODOR
Percent Volatiles by Volume:56

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO2.

Disposal

Waste Disposal Methods:PROD IS USEPA DEFENED EP TOXIC & IGNIT WASTE.
DISP OF AS AN E.P. TOX HAZ WASTE I/A/W LOC, STATE & FED REGS.
PRODUCT RELD INTO ENVIRONMENT MUST BE REPORTED TO THE NATIONAL
RESPONSE CENTER (1-800-424- 8 802). THE REPORTABLE QTY FOR PRODUCT
IS1 POUND.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.